Position Shutdown on the Zimmatic Vision
An independent guide from FixMyPivot, not from the manufacturer. Brand and panel names are here only so you can find your own equipment.
What it means
The pivot's position system has an error, often caused by the dead-reckoning setting on GPS machines.
There is an error with the position system. On machines with GPS, this is usually caused by the dead-reckoning setting. If that setting is too low, a brief and normal loss of signal can trigger the fault.
This one stops the machine.
Reading the display and looking the machine over with every door and cover closed is fine. Anything past that means power shut off and locked out at the main disconnect first, and electrical checks belong to a dealer, an electrician, or someone qualified to be in the panel.
This is what it means on the Zimmatic Vision. On a different panel the same light or message can mean something else. Wrong panel? Pick another Zimmatic panel.
Safety
Center pivots run on high voltage and heavy moving machinery. Shut off and lock out power at the main disconnect before you open a panel or touch anything electrical. If you are not sure, stop and call your local pivot dealer or a licensed electrician. These pages tell you what a code means. They do not replace a qualified technician, and the safety instructions that came with your equipment come first.
FixMyPivot is an independent troubleshooting service. It is not affiliated with, authorized by, or sponsored by any equipment manufacturer. All brand, panel and product names are trademarks of their owners and are used here only to identify the equipment a code appears on. This information is general, is provided as is without warranty, and may not match the software version on your panel. Use of these pages is subject to our Terms of Service.