- KEYPAD ERROR messageUsually means a button was held down too long, not a broken keypad
- Ghost keypad entriesKeys registering on their own can come from something resting on the keypad or a loose ground strapCall a technician
- Location display flashingNormal, it is alternating between two readings, not a fault
- Time Clock display flashingThe pivot reached a scheduled stop time and is waiting to be acknowledged
- Safety Circuit LED flashingMeans the safety circuit has been broken
- Low Pressure Shutdown at 0A shutdown setting of 0 usually means this protection is switched off
- PSI shown as On or OffMeans a pressure switch is fitted instead of a numeric reading
- Low Temperature ShutdownStops the pivot in cold weather and restarts once it warms up
- Low Pressure WarningWarns of low pressure but does not stop the pivot
- Pump Restart DelayThe pivot deliberately waits before restarting the pump after power loss
- Pressure Up DelayThe pump shut down because it took too long to reach pressureStops the machine
- Wind or Rainfall ShutdownMachine stopped because of a wind or rain setting, not a faultStops the machine
Safety
Center pivots run on high voltage and heavy moving machinery. Shut off and lock out power at the main disconnect before you open a panel or touch anything electrical. If you are not sure, stop and call your local pivot dealer or a licensed electrician. These pages tell you what a code means. They do not replace a qualified technician, and the safety instructions that came with your equipment come first.
FixMyPivot is an independent troubleshooting service. It is not affiliated with, authorized by, or sponsored by any equipment manufacturer. All brand, panel and product names are trademarks of their owners and are used here only to identify the equipment a code appears on. This information is general, is provided as is without warranty, and may not match the software version on your panel. Use of these pages is subject to our Terms of Service.